Manufacturer


Product Images

S6R

S6R

S6R by Quested Monitors

Introduction

The S6R is the smallest monitor in the S Range. It is a self-powered, 2-way active monitor. Its integral electronics and compact size make it an ideal choice where space is at a premium. It is fully magnetically shielded, so can be used in close proximity to CRT monitors and TVs.

The S6R's infinite baffle design and excessive amplifier headroom accumulate to provide a sonic performance that is truly remarkable for a box this size.

Typical applications include near-field monitoring for recording/mixing, programming, post production suites, broadcast and surround sound. The high power output enables the monitors to be used where high monitoring levels are required such as location work. The compact size allows for ease of placement of three or more units for LCR and multi-channel applications.

Although the bandwidth of the S6R is adequate for most situations, the low end performance can be further extended by combining it with an SB series sub bass. The two products make an ideal combination and extend the frequency response down to 20 Hz.

Specification
Size (WxHxD) 170(w) x 285(h) x 240(d) mm
Weight 7.5 kgs
Drivers Bass cone - 1 x 130 mm (5”)
High Frequency soft dome - 1 x 28 mm (11/8”)
Maximum SPL 104 dB (c) continuous pink noise @ 1 m (116 dB (c) per pair RMS music)
Frequency Response 75 Hz-22 kHz ± 2 dB
Input
Connector XLR and 1/4 inch Jack combo socket
Impedance 10k ohm electronically balanced with RF filters
Wiring Pin 1 ground Sleeve
Pin 2 hot Tip
Pin 3 cold Ring
Sensitivity -12 dBu to +6 dBu for 96 dB SPL @ 1 m set by 10 position rotary switch on rear
Filters
Subsonic -3dB @ 45 Hz, 24dB/oct
Ultrasonic -3dB @ 75 kHz, 4dB/oct
Crossover 1k19
LF EQ -2/-4 @ 82 Hz
HF EQ +/- 2dB @ 10 kHz
Power Amplifier
LF output power > 65W RMS continuous (note 1)
HF output power > 45W RMS continuous (note 1)
T.H.D. < 0.03% at levels up to 1 dB below clip, 20 Hz-20 kHz. typ 0.005% @ 1kHz.
Hum + Noise > -100 dB referred to clip
NOTE 1: The continuous rating is for a period not exceeding 5 minutes with unrestricted airflow (100 mm clearance) around the amplifier heatsinks and an ambient temperature not exceeding 30ºC.
Indication
Power on Front mounted green LED indicates power applied.
Clip Red LED 2 dB before amplifier clip.
Power requirements
Voltage Set by internal plugs: nominal 115V or 230V @ 50-60 Hz AC
230V setting: min 160V; restricted output power: max 255V
115V setting: min 80V; restricted output power: max 127V
Consumption Quiescent: 12W; Typical use: 45W (average music); Max: 90W (average music)
Note 0 dBu = 775 mV into open circuit